Two
areas of application: 1) bedrooms, 2) public areas & meeting
rooms.
Bedrooms
Mostmodern hotels have air conditioning fitted to client bedrooms. The client
requirements for room temperature can vary enormously, especially if they
have just arrived from overseas. Traffic noise and security issues mean
that bedroom windows are kept shut, so air conditioning is essential to
provide a comfortable environment for guests.
A small number
of rooms can be air conditioned at low cost using SRK type wall split
systems. These will have individual control, and can provide simple cooling
and heating operations.
Larger
hotels will require VRF systems, where one outdoor unit can be connected
to 40 (max.) indoor units. So that a 200 bedroom hotel would have approximately
5 outdoor units. All of these can be individually controlled, and can
be turned off if the room is unoccupied. VRF systems have variable speed
compressors (the primary drive of the heating/cooling system) which allow
energy saving at part load conditions. The variable speed is controlled
by an INVERTER in the outdoor unit, dependent on the combined demand of
the connected indoor units.
3D design staff
can assist with the selection and layout of systems for hotel bedrooms,
the routing of connecting pipework, drainage of condensate water from
internal units, and control schemes to suit the client’s requirements.
PC Windows based control systems can be linked, in order to ensure energy
is not wasted in unoccupied rooms, and set-back and group control can
be changed easily. Key card switches can be integrated into the room unit
control function, in order to save energy.
Indoor units
can be selected from:
|
FDQM Ducted – small
concealed units mounted in ceiling bulkhead next to bathroom |
|
FDTQ Cassette – small
cassette units also mounted in bulkhead |
|
FDK Wall mounted – high
level wall mounted units |
|
FDFL Floor standing
units – with cabinet |
|
FDFU Concealed
floor standing units, built in to enclosure out of sight. |
Full details of all
of these units can be found in the Products section
of this web site.
Meeting Rooms
This is a regular
source of revenue for hotels, and a growing requirement for developing
businesses to have meetings away from their office premises.
We would never
book a meeting room if it were not air conditioned. We have had bad experiences
of noise disturbance from traffic, aeroplanes, lawnmowers, building contractors,
etc. If we are shut up in a meeting room for 7 hours, air conditioning
is essential.
Small rooms
(< 8 people) can be air conditioned with a small wall mounted system,
or ducted system, or floor mounted unit. Larger rooms would require
FDTA Cassette or FDUMA Ducted systems, depending on their size, and
the type of construction.
Public Areas
Bars, restaurants,
reception area, fitness centre, lounge, all require heating, and are especially
welcoming in a hot humid summer if they are fitted with air conditioning.
Heat pump systems
are ideal for these locations; FDTA Cassette, and FDUMA Ducted systems are
the most suitable for these open plan areas. Larger areas may require
VRF systems, if there is a very mixed requirement for hating and cooling
in different zones. 3D technical staff will be able to advise on this. |
|